Citadel™ Series
Price range: $310.00 through $320.00
The Bantam Clean Power Citadel filters Line, Neutral, and Ground, delivering all the benefits of a bi-directional power conditioner and surge suppressor: harmonic attenuation, power factor correction, EMI/RFI reduction, and power-line emissions (PLE) protection.
Features include:
- Full-color LCD digital power meter
- Lab-quality 8/20 microsecond surge counter built in
- Real-time electrical telemetry: volts, amps, wattage, surge count, power factor, and more
- Never-fail, non-sacrificial series-mode design with no fans, relays, or switches
- Flexible desktop, rack, and wall mounting
Choose the RM1440A with a 120 V NEMA 5-15P input cordset, or the RM2880A with a 220-240 V NEMA 6-15P input cordset.
The Citadel by Bantam Clean Power elevates your electronics' performance and protects them from the unknown. Its custom information screen, featuring a lab-quality surge counter, reports on your electrical power environment in real time. The Citadel has eight outlets total: two on the front panel and six on the rear. The 120 V RM1440A adds two IEC 60320 C13 outlets and two supplied IEC-to-NEMA 5-15R adapters, giving you the flexibility to use IEC-only cordsets or power bricks (wall warts) without blocking adjacent outlets.
The Citadel is a three-wire, bi-directional power conditioner and surge suppressor with a color LCD display and multiple mounting options. Like every Bantam product, it delivers professional-grade power conditioning built for the systems your work depends on, not consumer-grade protection for inexpensive electronics.
Why Choose the Citadel™?
- Patented filtration and conditioning on all three wires (Line, Neutral, and Ground) for complete surge and noise protection.
- Never-fail, non-sacrificial component design with series-mode surge suppression that does not wear out, switch off, or stop protecting your investment.
- No moving parts: no fans, no relays, no switches.
- Suppresses power-line emissions (PLE): unwanted high-frequency signals that ride along power wiring, blocking them bi-directionally so they neither leak off your equipment nor couple onto it from the line.
- Color LCD display shows surge counter, volts, amps, power (watts), frequency (Hz), and power factor in real time.
- Does not dump harmful energy to ground the way consumer surge protectors do; the Citadel maintains a stable ground reference that digital equipment depends on.
- Filters EMI and RFI interference such as noise, hum, and harmful frequencies traveling along business and home power wiring.
- Provides harmonic attenuation and power factor correction.
- Flexible mounting: desktop (horizontal or vertical), 19-inch rack (1U), or wall mount.
Models
- RM1440A-US: 110-120 VAC version, 1440 VA.
- RM2880A-US: 220-230 VAC version, 2880 VA.
Electrical Ratings
| Specification | RM1440A (120 V) | RM2880A (240 V) |
|---|---|---|
| Input Voltage | 110-120 VAC, 60 Hz, cordset with NEMA 5-15P plug | 220-230 VAC, 50 or 60 Hz, cordset with NEMA 6-15P plug (optional IEC C20 inlet) |
| Output Voltage | 110-120 VAC, 60 Hz | 220-230 VAC, 50 or 60 Hz |
| Max Input/Output Voltage | 125 VAC, 60 Hz | 250 VAC, 50 or 60 Hz |
| Max Input/Output Current | 12 amperes RMS | 12 amperes RMS |
| VA Rating | 1440 VA | 2880 VA |
| Power Factor | 0.99 | 0.99 |
| Safety Standard | UL/IEC 62368-1 | UL/IEC 62368-1 |
| Agency Listing | UL (file E521973) | UL (file E521973) |
Performance Metrics
- Electrical Mode Protection: patented series normal and common mode.
- Harmonic Attenuation: up to 40% reduction of voltage and current noise up to 30 MHz.
- Power Factor Correction: up to 30% improvement.
- Electromagnetic Pulse (EMP): blocks EMP current the same as a surge, protecting Line, Neutral, and Ground paths.
- Surge Joule Rating: series-mode protection provides unlimited joule rating.
- Residual Surge: less than 1% of total surge current is allowed to pass through to the protected device.
- Clamping Voltage (typical, closed circuit): at 120 VAC, +/-10V (Neutral-Ground +/-10V); at 230 VAC, +/-20V (Neutral-Ground +/-20V).
EMI/RFI Noise Attenuation (Normal Mode)
| Frequency | Normal Mode Reactance | RM1440A Attenuation | RM2880A Attenuation |
|---|---|---|---|
| 60 Hz | 1.51 Ω | 0.30 dB | 0.14 dB |
| 180 Hz (3rd harmonic) | 4.52 Ω | 0.98 dB | 0.36 dB |
| 300 Hz (5th harmonic) | 7.54 Ω | 2.09 dB | 0.77 dB |
| 420 Hz (7th harmonic) | 10.55 Ω | 3.35 dB | 1.32 dB |
| 1 kHz | 25.12 Ω | 8.67 dB | 4.62 dB |
| 10 kHz | 251 Ω | 28.0 dB | 22.7 dB |
| 150 kHz | 3.77 kΩ | 51.5 dB | 46.2 dB |
| 1 MHz | 25.1 kΩ | 68.0 dB | 62.7 dB |
Physical / Environmental
- Enclosure: molded ABS/PVC UL94-V0 industrial-grade plastic.
- Dimensions: 11.75 in x 8.25 in x 1.75 in (299 mm x 210 mm x 44.5 mm), 1U high.
- Product weight: 6 lbs (2.72 kg).
- Storage temperature (ambient): -40° to 104° F (-40° to 40° C).
- Operating temperature (ambient): -40° to 104° F (-40° to 40° C).
- Indoor use only; rated for elevated data center temperatures (104° F).
Installation
- Desktop (vertical): supplied with sturdy molded bolted stands.
- Desktop (horizontal): supplied with soft feet and placement targets.
- Rack mount: supplied with metal ears for 19-inch racks; may also mount vertically in a zero-U configuration. Unit is 1U (1.75 in) high.
- Wall mount: two keyholes on the bottom of the enclosure for #10 panhead screws.
Intellectual Property
- U.S. Patents: 8,223,468; 11,775,645; 12,019,751; 12,271,477.
Additional information
| Input/Output Voltage | 110-120 VAC, 220-240 VAC, 85-250 VAC Wide-Range |
|---|