Citadel™ Series

The Bantam Clean Power Citadel filters Line, Neutral, and Ground, delivering all the benefits of a bi-directional power conditioner and surge suppressor: harmonic attenuation, power factor correction, EMI/RFI reduction, and power-line emissions (PLE) protection.

Features include:

  • Full-color LCD digital power meter
  • Lab-quality 8/20 microsecond surge counter built in
  • Real-time electrical telemetry: volts, amps, wattage, surge count, power factor, and more
  • Never-fail, non-sacrificial series-mode design with no fans, relays, or switches
  • Flexible desktop, rack, and wall mounting

Choose the RM1440A with a 120 V NEMA 5-15P input cordset, or the RM2880A with a 220-240 V NEMA 6-15P input cordset.

SKU: N/A Categories: , , ,

The Citadel by Bantam Clean Power elevates your electronics' performance and protects them from the unknown. Its custom information screen, featuring a lab-quality surge counter, reports on your electrical power environment in real time. The Citadel has eight outlets total: two on the front panel and six on the rear. The 120 V RM1440A adds two IEC 60320 C13 outlets and two supplied IEC-to-NEMA 5-15R adapters, giving you the flexibility to use IEC-only cordsets or power bricks (wall warts) without blocking adjacent outlets.

The Citadel is a three-wire, bi-directional power conditioner and surge suppressor with a color LCD display and multiple mounting options. Like every Bantam product, it delivers professional-grade power conditioning built for the systems your work depends on, not consumer-grade protection for inexpensive electronics.

 

Why Choose the Citadel™?

  • Patented filtration and conditioning on all three wires (Line, Neutral, and Ground) for complete surge and noise protection.
  • Never-fail, non-sacrificial component design with series-mode surge suppression that does not wear out, switch off, or stop protecting your investment.
  • No moving parts: no fans, no relays, no switches.
  • Suppresses power-line emissions (PLE): unwanted high-frequency signals that ride along power wiring, blocking them bi-directionally so they neither leak off your equipment nor couple onto it from the line.
  • Color LCD display shows surge counter, volts, amps, power (watts), frequency (Hz), and power factor in real time.
  • Does not dump harmful energy to ground the way consumer surge protectors do; the Citadel maintains a stable ground reference that digital equipment depends on.
  • Filters EMI and RFI interference such as noise, hum, and harmful frequencies traveling along business and home power wiring.
  • Provides harmonic attenuation and power factor correction.
  • Flexible mounting: desktop (horizontal or vertical), 19-inch rack (1U), or wall mount.

Models

  • RM1440A-US: 110-120 VAC version, 1440 VA.
  • RM2880A-US: 220-230 VAC version, 2880 VA.

Electrical Ratings

Specification RM1440A (120 V) RM2880A (240 V)
Input Voltage 110-120 VAC, 60 Hz, cordset with NEMA 5-15P plug 220-230 VAC, 50 or 60 Hz, cordset with NEMA 6-15P plug (optional IEC C20 inlet)
Output Voltage 110-120 VAC, 60 Hz 220-230 VAC, 50 or 60 Hz
Max Input/Output Voltage 125 VAC, 60 Hz 250 VAC, 50 or 60 Hz
Max Input/Output Current 12 amperes RMS 12 amperes RMS
VA Rating 1440 VA 2880 VA
Power Factor 0.99 0.99
Safety Standard UL/IEC 62368-1 UL/IEC 62368-1
Agency Listing UL (file E521973) UL (file E521973)

Performance Metrics

  • Electrical Mode Protection: patented series normal and common mode.
  • Harmonic Attenuation: up to 40% reduction of voltage and current noise up to 30 MHz.
  • Power Factor Correction: up to 30% improvement.
  • Electromagnetic Pulse (EMP): blocks EMP current the same as a surge, protecting Line, Neutral, and Ground paths.
  • Surge Joule Rating: series-mode protection provides unlimited joule rating.
  • Residual Surge: less than 1% of total surge current is allowed to pass through to the protected device.
  • Clamping Voltage (typical, closed circuit): at 120 VAC, +/-10V (Neutral-Ground +/-10V); at 230 VAC, +/-20V (Neutral-Ground +/-20V).

EMI/RFI Noise Attenuation (Normal Mode)

Frequency Normal Mode Reactance RM1440A Attenuation RM2880A Attenuation
60 Hz 1.51 Ω 0.30 dB 0.14 dB
180 Hz (3rd harmonic) 4.52 Ω 0.98 dB 0.36 dB
300 Hz (5th harmonic) 7.54 Ω 2.09 dB 0.77 dB
420 Hz (7th harmonic) 10.55 Ω 3.35 dB 1.32 dB
1 kHz 25.12 Ω 8.67 dB 4.62 dB
10 kHz 251 Ω 28.0 dB 22.7 dB
150 kHz 3.77 kΩ 51.5 dB 46.2 dB
1 MHz 25.1 kΩ 68.0 dB 62.7 dB

Physical / Environmental

  • Enclosure: molded ABS/PVC UL94-V0 industrial-grade plastic.
  • Dimensions: 11.75 in x 8.25 in x 1.75 in (299 mm x 210 mm x 44.5 mm), 1U high.
  • Product weight: 6 lbs (2.72 kg).
  • Storage temperature (ambient): -40° to 104° F (-40° to 40° C).
  • Operating temperature (ambient): -40° to 104° F (-40° to 40° C).
  • Indoor use only; rated for elevated data center temperatures (104° F).

Installation

  • Desktop (vertical): supplied with sturdy molded bolted stands.
  • Desktop (horizontal): supplied with soft feet and placement targets.
  • Rack mount: supplied with metal ears for 19-inch racks; may also mount vertically in a zero-U configuration. Unit is 1U (1.75 in) high.
  • Wall mount: two keyholes on the bottom of the enclosure for #10 panhead screws.

Intellectual Property

  • U.S. Patents: 8,223,468; 11,775,645; 12,019,751; 12,271,477.

Additional information

Input/Output Voltage

110-120 VAC, 220-240 VAC, 85-250 VAC Wide-Range